Medical Device Penetration Testing
05B — MEDICAL DEVICE PENTEST

Medical Device Penetration Testing (MDOT)

Secure connected healthcare devices before they become a liability. Patient safety is the scope.

What Is Medical Device Penetration Testing?

Medical Device Operational Technology (MDOT) penetration testing evaluates the security of connected medical devices — implantables, patient monitors, infusion pumps, diagnostic systems, and clinical workflows. Unlike standard IoT, medical devices carry direct patient safety consequences.

A vulnerability is not just a data breach. It is a treatment disruption, a misdiagnosis, or worse. Our testing methodology is built around this reality — every finding is evaluated for clinical impact, not just CVSS scores.

Scope of a Medical Device Pentest

From embedded firmware to clinical network integration.

Connected Devices

Infusion pumps, ventilators, patient monitors, wearable health devices. Embedded firmware, communication interfaces, safety-critical function manipulation.

Clinical Networks

HL7, FHIR, DICOM communication protocols. Integration with hospital information systems (HIS), electronic health records (EHR), and PACS.

Mobile and Cloud

Companion apps, telehealth platforms, cloud backends. API testing, data exposure, remote code execution paths.

Embedded Firmware

Firmware reverse engineering, binary analysis, secure boot assessment, update mechanism validation.

Hardware Interfaces

UART, JTAG, SPI, SWD debug interfaces. Physical tampering, fault injection, side-channel analysis.

Wireless Protocols

BLE, Wi-Fi, proprietary RF. Replay attacks, eavesdropping, unauthorized device pairing.

Testing Approaches

Two methodologies for different clinical contexts.

Grey Box

Non-intrusive assessment of deployed devices in clinical environments. Network traffic analysis, protocol evaluation, configuration review. Best for devices in active clinical use.

Best for: Deployed medical devices in active clinical environments.

White Box

Full access with engineering documentation. Firmware analysis, source code review, hardware interface testing. Best for premarket submission and compliance validation.

Best for: Premarket submission, compliance validation, R&D testing.

Our Approach

Patient safety drives every decision.

01

Threat Modeling

Device use cases, clinical workflows, attack surface mapping. STRIDE methodology applied to patient safety scenarios.

02

Vulnerability Discovery

Firmware analysis, protocol fuzzing, hardware probing, wireless assessment. Aligned with IEC 81001-5-1 security requirements.

03

Controlled Exploitation

Proof-of-concept demonstrating clinical impact. Tested in lab environments, never against active patient-connected systems.

04

Regulatory Reporting

Findings mapped to FDA premarket guidance, EU MDR, IEC 62304, and ISO 81001-5-1. Engineering-ready remediation guidance included.

Our Technical Expertise

Where cybersecurity meets patient safety.

FDA Premarket

Aligned with FDA premarket cybersecurity guidance for medical devices. Documentation supports 510(k) submissions and De Novo pathways.

IEC 81001-5-1

Security requirements for health software. Applied throughout the engagement to support TIR57 compliance.

IEC 62304

Medical device software lifecycle standard. Testing supports safety classification and risk management files.

Patient Safety First

Every finding evaluated for clinical impact. Risk rated by potential harm to patients, not just CVSS.

Request a Medical Device Pentest

Tell us about your device or clinical environment. We'll scope a safe, controlled engagement.

Get in Touch